IntelliSensor Fuel Level Sensor - 240 Ohms

Electronic sensor (no moving parts to break); Ideal for most hydrocarbon based liquid sensing applications; reverse polarity protected.
Parts --- Specifications --- Application Notes
If you want guidance in selecting a Fuel Level Sender check our "How to select a Fuel Sender" (Opens new window)
IntelliSensor Fuel Level Sensor (top)
Tank Depth Kit
11.0" 111058
13.0" 111059
15.0" 111060
19.0" 106596
20.0" 105696
22.0" 105697
24.0" 105699
26.0" 105701

SPECIFICATIONS:

Housing: Extruded aluminum, reinforced, internally baffled
Flange/opening/mounting: High-impact, moisture-resistant acetal, molded; standard SAE 5-hole flange, 1.65" (aprox. 42mm) diameter; 10-32 screws (5) for mounting (torque specification 12-15 in.lbs.)
Internal configuration: Patented variable capacitance technology with a pulse-width-modulation output (to interface with gauge)
Connections: Two wires standard (flying leads), 18-gauge color-coded; pink lead for sendor ground, black lead for ground
Ohms/resistance: 240-33.5 Ohms (240-260 Ohms at empty, 27.5-39.5 Ohms at full)
Operating voltage: 12/24 Volts
Accuracy: Empty (0-3%) and full (0+3%) per SAE J1810 requirements for primary and secondary calibration accuracy
Operating temperature: -40°C to +85°C
Operating media: Diesel fuels, hydraulic fluids, heating fuels, pure gasoline
Shock and Vibration: Per SAE J1810/4.4.2 and 4.5
Salt spray: Per SAE J1810/4.7.2 (5% salt solution at +38°C for 48 hours)
Water leakage: Per SAE J1810/4.8.2 (pressurized to 41 kPa +/-4 for one minute, no leaks allowed)
(top)

APPLICATIONS:

Suitability of application is the responsibility of the user.
Use in "contaminated" fuels and in applications where the percentage of water-to-fuel exceeds approximately 5% may impede normal operating performance and will void warranty.
Follow factory guidelines for installation to assure correct mounting of flange.
Cup supports or similar devices are recommended for non-vertical mounting in tank for most units.
Unit should be installed approximately 3/4" from bottom of tank.
Set point for empty is 1/8" full tank level.